Sunday, October 26, 2014

Wall STC and Fire Resistance Ratings

The online version of the Gypsum Association’s Fire Resistance Design Manual 20th Edition 2012 is here:

The Gypsum Association’s Fire Resistance Design Manual has both proprietary and generic wall systems with fire and STC ratings. Here are some generic STC ratings of walls we always use that should help you during the design phase, the GA-WP number is the Gypsum Association number:
·         1 layer 5/8” Gypsum Board each side 3-5/8” metal studs without insulation, GA-WP-1350, 1Hr, STC 35-39
·         1 layer 5/8” Gypsum Board each side 3-5/8” metal studs with insulation, GA-WP-1072, 1Hr, STC 45-49
·         1 layer 5/8” Gypsum Board one side, 2 layers gypsum board opposite side 3-5/8” metal studs without insulation, GA-WP-1052, 1Hr, STC 44
·         1 layer 5/8” Gypsum Board one side, 2 layers gypsum board opposite side 3-5/8” metal studs with insulation, GA-WP-1052, 1Hr, STC 50-54
·         2 layers 5/8” Gypsum Board each side 3-5/8” metal studs without insulation, GA-WP-1616, 2Hr, STC 45-49
·         2 layers 5/8” Gypsum Board each side 3-5/8” metal studs with insulation, GA-WP-1522, 2Hr,  STC  55-59

* The Gypsum Association’s Fire Resistance Design Manual does not have any generic wall systems with resilient furring channels, so if you need a higher STC rating you will need to go to a manufacturer’s tested system.



Monday, December 30, 2013

Building Code Resources

...a very useful post from copied in it's entirely from http://splankin.com/archiwiki/...

International Building Code (and all other International Codes…) Including the BCNYS Building Code of New York State
building code


OSHA and rooftops
Building code does not really cover rooftop issues. They leave it up to OSHA.

OSHA considers it a working area.
Here’s a booklet on stairs and ladders:
here’s one on fall protection:


NFPA – all National Fire Protection Association codes are online for free
Go to the website at:
and search for the code you are interested (for example NFPA 101 – Life Safety Code). Then, you will click through to the individual code. Part way down the page it will say:

Click  and log in. It will launch in a “real read” window (you probably have to install the real read plug-in). This is especially useful for the more obscure NFPA codes & standards such as NFPA 37 – Standard for the Installation and Use of Stationary Combustion Engines and Gas Tubines.
nfpa

UL Documents. UL Fire Resistance Directory
The famous orange book is online.
Walls, Roofs, floors:
fire rated joint systems:
Also, the UL fire resistance wizard!
UL

ICC/ANSI A-117 – what we commonly call ADA or accessibility code
Note that this is NOT the ADA code (that is federal). They also have the new, updated 2009 version.
ansi

Federal ADA manual (not to be confused with ANSI A-117).
ada

FM Global Roof Selection Tool
RoofNav is a complimentary tool from FM Approvals that provides access to the most up-to-date FM Approved roofing products and assemblies.
Designed to help roofing professionals, RoofNav provides easy access to all roofing-related information from the FM Approvals – Approval Guide and related installation recommendations from relevant FM Global Property Loss Prevention Data Sheets.
roof nav

Masonry Fire Resistance Ratings
NCMA the National Concrete Masonry Association has published this short but very useful guide to the fire resistance of concrete masonry (blocks). Shows also how to detail fire rated joints in CMU.
tek1
tek

Gypsum Association Fire Resistance Design Manual
usgyps

Fireproofing systems:
grace:
hilti:

Article about top of wall deflection and deflection track
this CSI article is a great discussion of the concerns regarding top of wall deflection and fire rating the top of wall deflection joint:

Fireproofing – thermally restrained vs unrestrained
ever wondered what UL is getting after when they say restrained versus unrestrained? read here:

Wednesday, September 28, 2011

Thermal Barriers and Ignition Barriers Unconfused

via the Spray Foam Industry website

Thermal Barriers
Building codes require that foam plastic insulation, such as spray polyurethane foam (SPF), be covered with a thermal barrier to slow their involvement in fire situations. Thermal barriers are discussed in the International Building Code (IBC) in Section 2603 and in the International Residential Code (IRC) in Section R314.
½-inch thick gypsum board is one commonly used thermal barrier. It and other thermal barriers are designed to "limit the average temperature rise of the unexposed [foam plastic insulation] surface to no more than 250 oF (121 oC) after 15 minutes of fire exposure to the ASTM E 119 standard time temperature curve." [IRC 2003, Section R314.1.2]
But, there are MANY exceptions to the thermal barrier requirement. For example:
1.     Building code authorities may approve coverings based on fire tests specific to the SPF application. For example, covering systems that successfully pass large scale tests (such as the small room corner test) may be approved by code authorities in lieu of a thermal barrier.
2.     SPF protected by a 25 mm (1-inch) thickness of masonry does not need a thermal barrier.
3.     Certain SPF roof covering systems do not require a thermal barrier between the SPF and the interior.
Ignition Barriers
Another exception to the thermal barrier requirement is in attics and crawl spaces where entry is made only for the service of utilities. In these cases, SPF must be protected from ignition by covering with 38 mm (1 1/2 inch) mineral fiber insulation, 6.4 mm (1/4 inch) wood structural panels, 9.5 mm (3/8 inch) gypsum board or other code prescribed material. These materials which offer protection from ignition are called "ignition barriers" (the building codes do not use the term "ignition barrier"; this term is a common vernacular used by the building trades to describe these and equivalent materials).
As with thermal barriers, code authorities may accept alternatives to the above prescribed based on fire tests specific to the SPF application.
In General
Materials which are not specifically prescribed by the building codes may be approved by building code authorities for use as a substitute or an exception to the requirement of a thermal barrier or ignition barrier when based on fire tests specific to the SPF application.
Just because a material is advertised as a "thermal barrier" or "ignition barrier" does not mean that it has been tested in conjunction with SPF and approved by a code agency or a local code official. Ask for test data and code body approvals, listings, or other written indications of acceptability under the code to be sure that the product selected offers the fire protection that the code demands.
For more information, refer to SPFA Document AY 126 Thermal Barriers for the Spray Polyurethane Foam Industry and API Document AX 230 Fire Safety Guidelines for Use of Rigid Polyurethane and Polyisocyanurate Foam Insulation in Building Construction.