Showing posts with label Div 23 Heating Ventilation and Air Conditioning. Show all posts
Showing posts with label Div 23 Heating Ventilation and Air Conditioning. Show all posts

Sunday, October 26, 2014

Installing fixed windows - Fine Homebuilding Tip

Fixed windows for passive solar heat gain:
Combine heavily insulated concrete and stud walls with fixed glass windows on the south side for direct gain.
Read more: http://www.finehomebuilding.com/how-to/tips/installing-fixed-windows.aspx#ixzz3HHCj2SRv 




Gypsum radiant wall, ceiling and floor panels - $10-12/sf + heat/cooling source

MESSANA AIR-RAY CONDITIONING LLC:
http://www.messana.it/en/


·        Energy efficiency and fuel savings of 50%-70%
·        60%-90%  less ductwork
·        Ultimate comfort
·        Aesthetically unobtrusive
·        Incredibly clean operation
·        Virtually silent operation
·        Fully integrated system; design, controls, delivery, sensors and circulation.


Some of the common questions have been:
·        What is the budget impact on our clients project if they are considering radiant?
·        What is the construction impact on our clients project if they are considering radiant?
·        How do these systems differ from “conventional” systems?
·        How many different methodologies of radiant delivery are used? What are the differences?
·        What methods of heating and cooling water can be used with radiant systems?
·        What are the pitfalls of using radiant on this project? For the client? For the contractor? For the design professional?
·        Why consider radiant heating and cooling?
·        What about response time of radiant systems?
·        How do you deal with condensation? Ventilation?


Jonathan Epps
Principal
SSCllc
“Building with reason”
Sustainable Sales Consulting, llc.
ph   607-277-2872
TF   888-250-8986

House Without Heating: Office Building in Austria - DETAIL-online.com

House Without Heating: Office Building in Austria - DETAIL-online.com
office building designed to guarantee continuous comfortable temperatures of between 22 and 26 degrees without heating, cooling or mechanical ventilation.
House Without Heating: Office Building in Austria by Baumschlager Eberle, façade

Monday, July 9, 2012

101: Hospital Architecture: Building as City

101: Hospital Architecture: Building as City via YouTube


This video describes some interesting concepts and solutions to hospital planning issues derived from studies and principles of urban growth.  Good to review whenever faced with a project (or site) that expects multiple future additions to follow the original.


From the description on YouTube:
This webinar introduces participants to fundamental issues in the planning and design of hospitals and medical centers including industry drivers for design, key planning and design considerations, basic hospital planning strategies and terms. It outlines and builds parallels between sound urban design principles and hospital planning and design. It also covers basic hospital building form types and organizational concepts.

Sunday, November 20, 2011

Zion National Park Visitor Center - Passive down-draft cooltower

Zion National Park Visitor Center

Pioneering Solar Buildings | via wikipedia

http://en.wikipedia.org/wiki/List_of_pioneering_solar_buildings

Trombe wall / solar chimney / passive heating


via Wikipedia - Common modifications to the Trombe wall include:
  • Exhaust vent near the top that is opened to vent to the outside during the summer. Such venting makes the Trombe wall act as a solar chimney pumping fresh air through the house during the day, even if there is no breeze.
  • Windows in the trombe wall. This lowers the efficiency but may be done for natural lighting or aesthetic reasons. If the outer glazing has high ultraviolet transmittance, and the window in the trombe wall is normal glass, this allows efficient use of the ultraviolet light for heating. At the same time, it protects people and furnishings from ultraviolet radiation more than do windows with high ultraviolet transmittance.
  • Electric blowers controlled by thermostats, to improve air and heat flow.
  • Fixed or movable shades, which can reduce night-time heat losses.
  • Trellises to shade the solar collector during summer months.
  • Insulating covering used at night on the glazing surface.
  • Tubes or water tanks as part of a solar hot water system.
  • Fish tanks as thermal mass.
  • Using a selective surface to increase the absorption of solar radiation by the thermal mass.
  • Also: Barra System

Eastgate Centre, Harare - Mick Pearce

The "termite mound building".
Eastgate Centre, Harare - Wikipedia, the free encyclopedia
http://inhabitat.com/building-modelled-on-termites-eastgate-centre-in-zimbabwe/
Because of its altitude, Harare has a temperate climate despite being in the tropics, and the typical daily temperature swing is 10 or 40 °C. This makes a mechanical or passive cooling system a viable alternative to artificial air-conditioning.